Klein Tools CL2500 User Manual

Instruction manual, Cl 2500

Advertising
background image

cuStOMER SERVIcE

KLEIN tOOLS, INc.

450 Bond Street

Lincolnshire, IL 60069

www.kleintools.com

139677 Rev. 11/13 B

ENGLISH

• 1000A Ac/Dc

• tRuE RMS

• AutO / MANuAL

RANGE

• NON cONtAct

VOLtAGE tEStER

• MAX / MIN / HOLD

• ANALOG BAR GRApH

• 3-5/6 DIGIt

5999 cOuNt LcD

• BAcKLIGHt

• WORKLIGHt

ENGLISH

8.

Non contact Voltage (NcV): > 25V Ac

SYMBOLS uSED ON LcD

~

Ac Measurement

Dc Measurement

-

Negative Dc Value

AT

Auto Range Active

O.L.

Overload: Range Exceeded

Apo

Auto power-Off Active

Low Battery

HOLD

Hold Active

MIN

Minimum Reading

MAX

Maximum Reading

%

Duty cycle Mode

Frequency Mode

V

Voltage Measurement

A

current in Amps

Ω

Resistance in Ohms

Diode test

F

capacitance in Farads

continuity test

Relative / Zero Mode

n

Nano 10

-9

µ

Micro 10

-6

m

Milli 10

-3

k

Kilo 10

3

M

Mega 10

6

ELEctRIcAL SpEcIFIcAtIONS

Dc Voltage Measurement

Range

Resolution

Accuracy

600mV ˜ 600V

0.1mV ˜ 0.1V

± (0.5% + 4 digits)

1000V

1V

± (0.8% + 10 digits)

Overload protection:

1000V

Ac Voltage Measurement

Range

Resolution

Accuracy

600mV ˜ 750V

0.1mV ˜ 1V

± (2.0% + 5 digits)

Overload protection:

750V RMS

Frequency Response:

45 to 400 Hz

Minimum Voltage for Frequency Measurement:

200mV

Response:

True RMS

Dc current Measurement

Range

Resolution

Accuracy

600µA

0.1µA

± (1.2% + 3 digits)

2000µA

1µA

60A

0.01A

± (2.5% + 15 digits)

600A ~ 1000A

0.1A ~ 1A

± (1.5% + 8 digits)

Overload protection:

Voltage:

600V RMS

current:

2000µA (leads), 1000A (clamp)

Ac current Measurement

Range

Resolution

Accuracy

600µA

0.1µA

± (2.0% + 5 digits)

2000µA

1µA

± (1.5% + 5 digits)

60A

0.01A

± (2.9% + 15 digits)

600A ~ 1000A

0.1A ~ 1A

± (1.9% + 8 digits)

Overload protection:

Voltage:

600V RMS

current:

2000µA (leads), 1000A (clamp)

Frequency:

45 to 400Hz

Minimum current for Frequency Measurement:

400µA (leads) or 20A (clamp)

Response:

True RMS

Resistance Measurement

Range

Resolution

Accuracy

600

Ω ˜ 6MΩ

0.1

Ω ˜ 0.001MΩ

± (1.0% + 4 digits)

60M

Ω

0.01M

Ω

± (2.0% + 4 digits)

Overload protection:

600V RMS

capacitance Measurement

Range

Resolution

Accuracy

60nF ˜ 6000µF

0.01nF ˜ 1µF

± (3.5% + 6 digits)

Overload protection:

600V RMS

Frequency Measurement

Range

Resolution

Accuracy

99.99Hz ˜ 499.9kHz

0.01Hz ˜ 100Hz

± (0.1% + 4 digits)

Overload protection:

600V RMS

Duty cycle Measurement

Range

Resolution

Accuracy

0.1 ˜ 99.9%

0.1%

± (0.2% per kHz + 0.1% + 5 digits)

Overload protection:

600V RMS

Diode test

Overload protection

Range

test current

Open circuit Voltage

600V RMS

6.0V

Appx. 0.25mA

< 1.8V DC

continuity test

Overload protection

Open circuit Voltage

threshold (Appx.)

600V RMS

< 0.44V

~40

Ω

Non contact Voltage Detector

On Voltage

Appx. 25V AC and above

WARRANtY

www.kleintools.com/warranty

cLEANING

Turn instrument off and disconnect test leads. Clean the instrument by using

a damp cloth. Do not use abrasive cleaners or solvents.

StORAGE

Remove the batteries when instrument is not in use for a prolonged period of

time. Do not expose to high temperatures or humidity. After a period of storage

in extreme conditions exceeding the limits mentioned in the Specifications

section, allow the instrument to return to normal operating conditions before

using it.

DISpOSAL / REcYcLE

caution:

This symbol indicates that equipment and its accessories

shall be subject to a separate collection and correct disposal.

750V

1000V

1000A

Dwg Name:

CL2500-139677ART Dwg No: 139677

ECO No:

14678 Pkg Dwg Ref: 1650 Rev: B

Color Reference:

CEN-PACK-003-A

Instruction Manual