for Professionals...Since 1857

®

ENGLISH

ET510

• 2.4" cOLOr LcD

• BrIGHT LED WOrkLIGHT

• IP67 GOOSENEck caMEra

• ScrEEN MIrrOr

• aUTO POWEr Off

WarraNTy

This product is warranted to be free from defects in materials and
workmanship for a period of two years from the date of purchase. During
this warranty period, Klein Tools has the option to repair, replace or refund
the purchase price of any unit which fails to conform to this warranty under
normal use and service. This warranty does not cover damage which occurs
in shipment or failure which results from alteration, tampering, accident,
misuse, abuse, neglect, or improper maintenance. Batteries and damage
resulting from failed batteries are not covered by warranty. A purchase receipt
or other proof of original purchase date will be required before warranty
repairs will be rendered.
Any implied warranties, including but not limited to implied warranties of
merchantability and fi tness for a particular purpose, are limited to the express
warranty. Klein Tools shall not be liable for loss of use of the instrument or
other incidental or consequential damages, expenses, or economic loss, or for
any claim or claims for such damage, expenses or economic loss.
Some states or countries laws vary, so the above limitations or exclusions
may not apply to you. This warranty gives you specifi c legal rights, and
you may also have other rights which vary from state to state. If your Klein
product requires repair or for information on how to exercise your rights
under the terms of this warranty, please contact Klein Tools at 1-800-553-
4676.

cLEaNING

Turn instrument off and disconnect gooseneck camera. Clean the instrument and
camera by using a damp cloth. Do not use abrasive cleaners or solvents.

STOraGE

Do not expose to high temperatures or humidity. After a period of storage in
extreme conditions exceeding the limits mentioned in the Specifi cations section,

allow the instrument to return to normal operating conditions before using it.

DISPOSaL / rEcycLE

caution:

This symbol indicates that equipment and its accessories

shall be subject to a separate collection and correct disposal.

SETUP

cHarGING
The rechargable lithium-ion battery should be charged before operating

the borescope for the fi rst time. The battery can be charged via a standard

120V wall outlet or through a computer USB port. An exhausted battery

will take up to 5 hours to charge. It can be left charging overnight without

needing to be removed from power. The expected lifetime of the included

battery is 500 charging cycles.

WALL OUTLET: Locate the power wall

adapter (f) and the USB cable (g). Remove

the soft input cover and plug the cable

into the borescope's USB port (7). Plug

the other end of the cable into the power

adapter, and plug the wall adapter into a

standard 120V outlet.

COMPUTER: Locate the USB cable (g).

Remove the soft input cover and plug

the cable into the borescope's USB port

(7). Plug the rectangular end into your

computer's USB port.

aTTacHING THE GOOSENEck caMEra
Locate the gooseneck camera (10). Plug it into the camera input socket

of the borescope. Rotate the

adjustment piece clockwise to lock

it into place. The white arrow on the

camera head should be pointing up.

POWErING ON/Off
To power the unit on and off, press and release the power button (2). The

borescope will be operational in a few moments.

LIVE VIDEO MODE

On startup, the borescope will enter the live output mode. The screen will

show the live output of the gooseneck camera along with the estimated

battery life remaining and the auto power off symbol if it is active.

LED BrIGHTNESS
The borescope gooseneck camera head has several LEDs used to light

your work area. You can control the brightness using the up and down

arrow buttons (3 & 4). The LED brightness ranges from off (LED:0) to full

(LED:100). The default setting is 25.

MIrrOrING caMEra OUTPUT
Press the mirror button (5) to mirror the camera output vertically over

the x-axis. This feature is useful when reading text or using the mirror

attachment with the borescope.

aUTO POWEr Off
The borescope can power itself off after 5 or 10 minutes of non-use, or

this feature can be disabled. Press and hold the "mirror" button for three

seconds until "APO" appears on the screen. Press repeatedly to toggle

between off, 5 min, and 10 min. The "APO" prompt will disappear after 5

seconds. A clock icon will appear in the top left corner of the screen when

auto power off is active.

BaTTEry MaINTENaNcE

Please contact Klein Tools customer service at 1-800-553-4676 to make

arrangements for battery replacement.

cUSTOMEr SErVIcE

kLEIN TOOLS, INc.

450 Bond Street Lincolnshire, IL 60069

1-800-553-4676 • www.kleintools.com

139730

Rev. 04/12 B

© 2012.

ET510-139730ART-English.indd 1-4

5/29/12 4:01 PM

Advertising
Table of contents