Klein Tools CL1000 User Manual

Instruction manual, Cl 1000

Advertising
background image

CUSTOMER SERVICE

KLEIN TOOLS, INC.

450 Bond Street

Lincolnshire, IL 60069

www.kleintools.com

139537T Rev. 11/13 B

ENGLISH

• AUTO / MANUAL

RANGE

• NON CONTACT

VOLTAGE
TESTER

• DATA HOLD

• MAX / MIN

• BAR GRAPH

• 3-3/4 DIGIT

3999 COUNT LCD

• BACKLIGHT

• WORKLIGHT

V

AT

0

10

20

40

30

Apo

600V

400A

CATIII

CL1000

ENGLISH

SYMBOLS USED ON LCD

~

AC Measurement

DC Measurement

-

Negative DC Value

AT

Auto Range Active

O.L.

Overload: Range Exceeded

Apo

Auto Power-Off Active

Low Battery

HOLD

Hold Active

MIN

Minimum Reading

MAX

Maximum Reading

%

Duty Cycle Mode

Frequency Mode

V

Voltage Measurement

A

Current in Amps

Ω

Resistance in Ohms

Diode Test

F

Capacitance in Farads

Continuity Test

n

Nano 10

-9

µ

Micro 10

-6

m

Milli 10

-3

k

Kilo 10

3

M

Mega 10

6

PRESS

and

HOLD

600V

400V

CA

TII

I

CL1000

PRESS

and

HOLD

8.

Non Contact Voltage (NCV): > 25V AC

ELECTRICAL SPECIFICATIONS

DC Voltage Measurement

Range

Resolution

Accuracy

400mV ˜ 400V

0.1mV ˜ 0.1V

± (0.5% + 4 digits)

1000V

1V

± (0.8% + 10 digits)

Overload Protection:

1000V

AC Voltage Measurement

Range

Resolution

Accuracy

400mV ˜ 750V

0.1mV ˜ 1V

± (2.0% + 5 digits)

Overload Protection:

750V RMS

Frequency Response:

40 to 400 Hz

Minimum Voltage for Frequency Measurement:

200mV

Response:

Averaging

DC Current Measurement

Range

Resolution

Accuracy

400µA

0.1µA

± (1.2% + 3 digits)

2000µA

1µA

Overload Protection:

Voltage:

600V RMS

Current:

2000µA

AC Current Measurement

Range

Resolution

Accuracy

400µA

0.1µA

± (2.0% + 5 digits)

2000µA

1µA

± (1.5% + 5 digits)

40A

0.01A

± (2.9% + 15 digits)

400A

0.1A

± (1.9% + 8 digits)

Overload Protection:

Voltage:

600V RMS

Current:

2000µA

Frequency:

45 to 400Hz

Minimum Current for Frequency Measurement:

400µA or 20A

Response:

Averaging

Resistance Measurement

Range

Resolution

Accuracy

400

Ω ˜ 4MΩ

0.1

Ω ˜ 0.001MΩ

± (1.0% + 4 digits)

40M

Ω

0.01M

Ω

± (2.0% + 4 digits)

Overload Protection:

600V RMS

Capacitance Measurement

Range

Resolution

Accuracy

40nF ˜ 4000µF

0.01nF ˜ 1µF

± (3.5% + 6 digits)

Overload Protection:

600V RMS

Frequency Measurement

Range

Resolution

Accuracy

9.999Hz ˜ 999.9kHz

0.001Hz ˜ 0.1kHz

± (0.1% + 4 digits)

Overload Protection:

600V RMS

Duty Cycle Measurement

Range

Resolution

Accuracy

0.1 ˜ 99.9%

0.1%

± (0.2% per kHz + 0.1% + 5 digits)

Overload Protection:

600V RMS

Diode Test

Overload Protection Range Test Current

Open Circuit Voltage

600V RMS

2.0V

Appx. 0.25mA

< 1.6V DC

Continuity Test

Overload Protection

Open Circuit Voltage

600V RMS

< 0.44V

Non Contact Voltage Detector

On Voltage

Appx. 25V AC

WARRANTY

www.kleintools.com/warranty

CLEANING

Turn instrument off and disconnect test leads. Clean the instrument by using

a damp cloth. Do not use abrasive cleaners or solvents.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of

time. Do not expose to high temperatures or humidity. After a period of storage

in extreme conditions exceeding the limits mentioned in the Specifications

section, allow the instrument to return to normal operating conditions before

using it.

DISPOSAL / RECYCLE

Caution:

This symbol indicates that equipment and its accessories

shall be subject to a separate collection and correct disposal.

750V

1000V

400A

Dwg Name:

CL1000-139537TART Dwg No: 139537T

ECO No:

14678 Pkg Dwg Ref: 1650 Rev: B

Color Reference:

CEN-PACK-003-A

Instruction Manual

CL

1000

CL1000 Instruction Manuals - MASTER.indd 1-4

11/20/2013 3:03:50 PM

Advertising