KV2 Audio EX12 User Manual

Page 8

Advertising
background image

EX12 USER’S GUIDE

P. 8

operating level. This type of protection allows the phase

response of the system to remain unchanged as the

level is lowered. Buy not compressing or limiting peak

signal, dynamics also remain unchanged. The control

objective is to regulate the operating temperature of the

transducers magnetic circuits log term. This ensures no

impact on performance due to power compression and

allows the components to retain their ability to repro-

duce high dynamics.

LED Status Lights

The EX12 control panel uses two distinct LED’s to

provide operating status information.

Power On / Limiter LED

This LED turns green when the speaker is turned ON.

The light will continue to be green during normal opera-

tion of the speaker system. Should the rms limiting

system be engaged due to overdriving of the EX12,

the LED will change color from green to yellow. The

audible effect of the rms limiter is a lowering of overall

output level. The rms limiter will disengage only if the

input level is turned down.

Signal / Thermal LED

This LED turns green when there is audio signal pres-

ent in the EX12. This signal indicator can be used to

troubleshoot wiring problems. The LED will change

from green to yellow under a thermal condition result-

ing from overheating of the amplifier system. Under this

condition, the speaker system will shut down. You can

expect for the system to be down for at least 2-3 min-

utes depending the ambient temperature and whether

the system is being exposed to direct sun light.

NOTE

: The EX12 features a finless

heatsink that allows it to operate in any posi-

tion. There is also an internal fan located inside the

amplifier module. The fan speed is dependent on

two factors; the temperature of the heat sink and the

output level of the speaker. As temperature increas-

es, so does fan speed. As audio level increases, fan

speed also increases as a preventative measure

designed to keep the heat sink temperature low.

Under normal operating conditions, the fan noise

remains inaudible. Please contact KV2 Audio or a lo-

cal service representative should the system enter a

thermal condition under normal operating conditions.

Stage Monitor Filter

The EX12 features a 90 Hz Monitor Filter control. De-

pressing the button engages a low pass audio filter al-

lowing the speaker to be effectively used to reproduce

frequencies above 90Hz.

CHAPTER 2: AUDIO SIGNAL