Technical data – Lenze E82ZWBRB User Manual

Page 25

Advertising
background image

Technical data

Rated data

2

EDK82ZWBRB DE/EN/FR 2.0

25

l

H1_Daten−82WBRB_BemDat_EN

Permissible switching rates

Recommended brake

Power

Coil: voltage 205 VDC

Permissible switching rate

Type

P [W]

L [H]

I [A] (20 °C)

[1/min]

BFK457−06E
BFK458−06E

20

76

0.10

60

BFK457−08E
BFK458−08E

25

66

0.12

60

BFK457−10E
BFK458−10E

30

85

0.15

60

BFK457−12E
BFK458−12E

40

107

0.20

40

BFK457−14E
BFK458−14E

50

102

0.24

30

BFK457−16E
BFK458−16E

55

127

0.27

20

BFK457−18E
BFK458−18E

85

100

0.41

10

BFK457−20E

1)

BFK458−20E

1)

100

115

0.49

8

BFK457−25E

1)

BFK458−25E

1)

110

134

0.54

6

1)

Operation only permitted if the brake switch is mounted in the control cabinet