8 diagnostics, Led status displays, Diagnostics – Lenze E94AYCCA User Manual
Page 46: 8diagnostics

8
Diagnostics
LED status displays
EDK94AYCCA DE/EN/FR/ES/IT 3.0
46
l
H1_Diagnose−Signalisierung DR303
8
Diagnostics
LED status displays
E94YCCA001D
LED
Description
Pos.
Colour
Condition
MS
green
On
The communication module is supplied with voltage and
connected to the standard device.
blinking
The communication module is supplied with voltage but not
connected to the standard device. (The standard device is either
switched off, in the initialisation phase or not available.)
DE
red
On
The communication module is not accepted by the standard
device.
BS
green
The table below lists the signalling of the BS and BE bus LEDs.
The control of the LEDs complies with CiA specification DR−303−3.
BE
red
Status display (LED)
Explanation
Connection status to the bus with the following signalling:
off
No connection to the master
green
CANopen status ("
S
")
red
CANopen fault ("
F
")