Connection data, 6electrical installation – Lenze E94AZHX0051 User Manual
Page 32
Electrical installation
Connection data
EDK94AZHX DE/EN/FR/ES/IT 3.0
32
l
H1_E_INST−Verdr_2_BL_EN
Connection data
Terminal X107
Labelling
Description
Connection of the motor holding brake
BD1
BD2
+ (Lenze: WH)
− (Lenze: BN)
E94AZHX0051: 24 V DC, max. 2.5 A
Observe correct polarity!
+ / −
Supply voltage for the motor holding brake
(18 ... 30 V DC)
Observe correct polarity!
SSP940X107
)
Note!
The supply terminals (+/−) are protected against polarity reversal.
The supply status can be reported to the basic device via the error channel.
Further information can be obtained from the documentation of the basic
device.
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Single core
0.25 ... 2.5
24 ... 12
0.5 ... 0.6
4.4 ... 5.3
2 conductors
1)
0.25 ... 1.5
24 ... 16
1)
Two conductors of the same cross−section with a twin wire end ferrule