4 technical data, General data, Technical data – Lenze E94AYCPM User Manual
Page 35

Technical data
General Data
4
EDK94AYCPM DE/EN/FR/ES/IT 6.0
35
l
H1_Daten−GHB Servo Drives 9400
4
Technical data
General Data
Area
Values
Order designation
E94AYCPM
Communication profile
PROFIBUS DP−V1
PROFIBUS DP−V0
PROFIBUS node
Slave
PNO identification number
0x07A8
Interfaces
9−pole Sub−D socket
Communication medium
RS485
Network topology
Line (without repeater), tree/line (with repeater)
Number of slaves
Max. 31 (without repeater), max. 125 (with repeater)
Max. cable length
1200 m (depending on the baud rate selected and the cable type
used)
Baud rate for cable type A (EN
50170)
9.6 kbps ... 12 Mbps (automatic detection)
Voltage supply
External supply via 2−pole plug connector
l
"+": U = 24 V DC (20.4V−0% ... 28.8V+0%), I = 130 mA
l
"−": reference potential for external voltage supply
Conformities, approvals
l
CE
l
UL
,
"Servo Drives 9400" hardware manual
Here you can find the ambient conditions and the electromagnetic
compatibility (EMC) specifications applying to the communication module.