8 diagnostics, Led status displays, Diagnostics – Lenze E94AYCPM User Manual
Page 47

Diagnostics
LED status displays
8
EDK94AYCPM DE/EN/FR/ES/IT 6.0
47
l
H1_Diagnose−KompModul Anzeigeelemente
8
Diagnostics
LED status displays
E94YCIB001F
LED
Description
Pos.
Colour
Condition
MS
Green
On
The communication module is supplied with voltage and
connected to the standard device.
Blinking
The communication module is supplied with voltage, but has no
connection to the standard device. (The standard device is
switched off, initialising, or not present.)
ME
Red
On
An error in the communication module has occurred.
BS
Green
Blinking
Communication via the communication module has been
established. PROFIBUS communication is active.
BE
Red
On
Bus monitoring has been triggered.
DE
Red
On
The communication module is not accepted by the standard
device. (See notes in the documentation for the standard device.)