7 maintenance, 1 maintenance intervals, Maintenance – Lenze 12xxx-52xxx Gearboxes User Manual
Page 20: Maintenance intervals, 7maintenance, Stop
![background image](/manuals/565838/20/background.png)
Maintenance
Maintenance intervals
7
l
20
BA 12.0028−EN 6.0
7
Maintenance
7.1
Maintenance intervals
ƒ
The mechanical power transmission system is free of maintenance.
ƒ
Shaft seals and roller bearings:
– The service life depends on the operating conditions.
– Replace seals in case of leakage to avoid consequential damage.
ƒ
Lubricants are subject to natural aging and must be replaced at regular intervals:
– The type of lubricant is indicated on the nameplate. If not indicated, please see
"List of lubricants" (Tab. 2).
– Only use similar lubricants when changing the lubricant.
– For maintenance intervals: see Tab. 2 "List of lubricants".
(
Stop!
Also observe the maintenance intervals for the other drive components!
Gearbox type
Lubricant
Change intervals
Type
Specification
Ambient
temperature
Note
Helical gearboxes,
helical−bevel gearboxes,
shaft−mounted
gearboxes
CLP 460
Oil on mineral basis
with additives
0
_C ... + 40 _C
16,000 operating hours − no
longer than three years (oil
temperature 70...80
_C)
Worm gearboxes,
helical−worm gearboxes
CLP−PG 460
CLP−PG 220
Oil on synthetic basis
(polyglycol)
−20
_C ... + 40 _C Do not mix with
mineral oils
25,000 operating hours − no
longer than three years (oil
temperature 70...100
_C)
All gearbox types
CLP−HC 220
(H1)
Food−compatible oil
on synthetic basis
−20
_C ... + 40 _C Approval to
USDA H1
16,000 operating hours − no
longer than three years (oil
temperature 70...80
_C)
All gearbox types
CLP−E 320
Biodegradable
diester oil on
synthetic basis
−20
_C ... + 40 _C Water pollution
class 0
16,000 operating hours − no
longer than three years (oil
temperature 70...80
_C)
Tab. 2
List of lubricants