7 maintenance, 1 maintenance intervals, Maintenance – Lenze 12xxx-52xxx Gearboxes User Manual

Page 20: Maintenance intervals, 7maintenance, Stop

Advertising
background image

Maintenance

Maintenance intervals

7

l

20

BA 12.0028−EN 6.0

7

Maintenance

7.1

Maintenance intervals

ƒ

The mechanical power transmission system is free of maintenance.

ƒ

Shaft seals and roller bearings:
– The service life depends on the operating conditions.
– Replace seals in case of leakage to avoid consequential damage.

ƒ

Lubricants are subject to natural aging and must be replaced at regular intervals:
– The type of lubricant is indicated on the nameplate. If not indicated, please see

"List of lubricants" (Tab. 2).

– Only use similar lubricants when changing the lubricant.
– For maintenance intervals: see Tab. 2 "List of lubricants".

(

Stop!

Also observe the maintenance intervals for the other drive components!

Gearbox type

Lubricant

Change intervals

Type

Specification

Ambient

temperature

Note

Helical gearboxes,
helical−bevel gearboxes,
shaft−mounted
gearboxes

CLP 460

Oil on mineral basis
with additives

0

_C ... + 40 _C

16,000 operating hours − no
longer than three years (oil
temperature 70...80

_C)

Worm gearboxes,
helical−worm gearboxes

CLP−PG 460
CLP−PG 220

Oil on synthetic basis
(polyglycol)

−20

_C ... + 40 _C Do not mix with

mineral oils

25,000 operating hours − no
longer than three years (oil
temperature 70...100

_C)

All gearbox types

CLP−HC 220

(H1)

Food−compatible oil
on synthetic basis

−20

_C ... + 40 _C Approval to

USDA H1

16,000 operating hours − no
longer than three years (oil
temperature 70...80

_C)

All gearbox types

CLP−E 320

Biodegradable
diester oil on
synthetic basis

−20

_C ... + 40 _C Water pollution

class 0

16,000 operating hours − no
longer than three years (oil
temperature 70...80

_C)

Tab. 2

List of lubricants

Advertising