About this documentation – Lenze EY System cables and system connectors User Manual
Page 19

About this documentation
Code for core colour coding according to DIN IEC 757
l
19
EDSYPFLD EN 8.0
Meaning
Symbol
Flame−resistant according to UL 1581, vertical wire flame test (VW−1)
Flame−resistant according to CSA C22.2 No. 3−92, vertical flame (FT−1)
Flame−resistant according to EN 50265−1/IEC 60332−1
General resistance to dilute acids, alkalis and detergents
General resistance to dust (e.g. bauxite, magnesite)
silicone
Silicone−free
halogen
Halogen−free according to VDE 0472, part 815
LBS
Free of paint−wetting impairment substances
oil
Oil resistance according to ISO 6722, parts 1 and 2
Oil resistance according to VDE 0282, part 10
Oil resistance according to VDE 0472, part 803, test method B
fuel
Resistance to fuels according to ISO 6722, parts 1 and 2
UV
UV resistant and weatherproof according to DIN EN ISO 4892−2
1.6
Code for core colour coding according to DIN IEC 757
Abbreviation Colour
Abbreviation Colour
Abbreviatio
n
Colour
BK
Black
BN
Brown
RD
Red
YE
Yellow
GN
Green
BU
Blue
VT
Violet
GY
Grey
WH
White
PK
Pink
GNYE
Green/Yello
w
OG
Orange