6

Electrical installation

Synchronisation of the standard device

EDK2192IB DE / EN / FR 2.0

42

l

H2_Synchronisation_Grundgeraet−2192ECAT_Synchronisation_Grundgeraet

Synchronisation of the standard device

The synchronisation of the standard device via the EtherCAT fieldbus ˘ if it is supported ˘
can be carried out via the 3−pin plug connector with screw connection (sync).

)

Note!

ECS servo system

ƒ

For the ECS axis modules, a synchronisation with operating system
software version

³ 8.3 is possible.

ƒ

For the ECS power supply module a synchronisation is not supported.

Wire ...
ƒ terminal "0" to the corresponding sync input of the standard device (see

documentation of the standard device).

ƒ the sync supply to the 24V supply of the communication module or the standard

device.

Opto

0

EtherCAT-

Sync

W

2192ECAT002

Terminal

Description

+

External sync supply (SELV/PELV)
U = 24 V DC (20.4 V − 0 % ... 28.8 V + 0 %)

0

Sync output
(t = 150

m

s, I

max

= 10 mA at 24 V)

Reference potential for external sync supply