Switch unit - installation – Lenze E82ZBS020 User Manual

Page 11

Advertising
background image

Switch unit - Installation

EDK82ZBX020 3.0

l

- 5 -

Application examples 8200 motec:
Reversal of direction of rotation (CCW - Stop - CW) with Standard I/O or

Application I/O

Ÿ Deceleration after STOP along the quick stop ramp (C0105).

Ÿ Deceleration and acceleration after a reversal of the direction of rotation along ramps C0013 and

C0012.

Example for terminal configuration C0007 = -16-

28

E3

E2

E 39

20

X3

Terminal assignment

28

E3

E2

E4 39

20

7

X3

‚

X3/20

Brown wire
DC supply +20 V
Jumper to X3/28 (CINH)

CW

CCW

0



X3/E3

White wire = CW rotation
(CW/QSP on X3/E3)

CW

CCW

0



E82ZBSP001

X3/E4

Green wire = CCW rotation
(CCW/QSP on X3/E4)



Switch unit

‚

Jumper only for Standard I/O

CW

CW rotation

Parameterisation C0007

CW

CW rotation

0

Stop

CCW

CCW rotation

C0007 = -16-

You can parameterise the terminal configuration using C0410 as desired
(see Operating Instructions)

Start/Stop (CINH) with any function module

STOP

START

START

STOP

28 39

20

7

X3



0

0

Terminal assignment

STOP

START

START

STOP

28 39

20

7

X3



0

0

X3/20

Brown wire
DC supply +20 V

STOP

START

START

STOP

28 39

20

7

X3



0

0

X3/28

White wire = CINH

STOP

START

START

STOP

28 39

20

7

X3



0

0

E82ZBSP002

Green wire = not used



Switch unit

STOP

Controller inhibited

0

Controller inhibited

START

Controller enabled

Green wire = not used
Appropriate insulation!

• Instead of using X3/28 digital input, (X3/E1 ... X3/E6) can also be

connected and thus different digital functions (e.g. fixed frequency
JOG1 at E1) can be activated.

• For instance, fixed frequency JOG1 at E1.