2 technical data, General data and operating conditions, Technical data – Lenze ELM3−010H010 User Manual

Page 24: 2technical data

Advertising
background image

2

Technical data

General data and operating conditions

EDKLM3−XXX−002 DE/EN/FR 1.0

24

l

H1_Daten−Abmessungen ELM3−002_Tab

2

Technical data

General data and operating conditions

Standards

Conformity

CE

Low−voltage Directive (2006/95/EC)

Protection

Type of protection

EN 60529

IP 20

Not in the wire range of
the terminals

NEMA 250

Protection against contact to
type 1

Insulation resistance

EN 61800−5−1

Overvoltage category III
> 2000 m: Overvoltage category II

Leakage current

EN 61800−5−1

> 3.5 mA

Observe regulations
and safety instructions!

Ambient conditions

Temperature

Storage

−25 ... +60 °C

Transport

−25 ... +70 °C

Operation

−10 ... +55 °C
Current derating from +40 to +55 °C: 2.5 %/°C

Site altitude

0 ... 4000 m amsl
1000 ... 4000 m amsl: Current derating by 5 %/1000 m

Pollution

EN 61800−5−1

Pollution degree 2

Vibration resistance

EN 50178; IEC
61800−5−1;
Germanischer
Lloyd, general
conditions

Acceleration−resistant up to 0.7 g

Advertising
This manual is related to the following products: