Lenze E94P v2.0 User Manual

Page 8

Advertising
background image

8

P940HBK01B

WAITENABLE:

WAIT UNTIL IN_A3

; wait until A3 - hardware “enable” closed

ENABLE

; enable/start drive (& brake if assigned)

WAIT TIME 1000

; wait 1 second to release brake

OUT2 = 1

; Release Brake

WAIT TIME 1000

; Wait 1 sec.

VAR_REFERENCE = 0

; external reference for speed control

OUT1 = 0

; clear “fault” outputs

V0 = 0

Again:

; Empty loop does nothing while the motor spins

GOTO Again

; execute motions in the loop

END

; shouldn’t get here anyway

;-------------------------------------------------------------------------------

;The Fault handling code below directs the code execution here when a fault

occurs

;-------------------------------------------------------------------------------

PROCESSFAULT:

V0 = DFAULTS

; do this so you can see that it was a fault

OUT1 = 1

; indicate fault on LED output too

IF DFAULTS == 36

; user switch disabled

IREF = 0

; set internal speed reference to zero

VAR_REFERENCE = 1 ; select Internal reference

WAIT TIME 1000

; Wait 1 sec. (for motor to stop)

OUT2 = 0

; engage Brake

DISABLE

; disable outputs (incl. brake if assigned)

GOTO START

; reinitialize and wait for user to enable

ENDIF

GOTO WAITENABLE

; continue program

;********************************* Fault Handling Code ************************

ON FAULT

RESUME PROCESSFAULT

ENDFAULT