Connection incremental encoder with ttl level, Electrical installation, Stop – Lenze EPZ-10203 User Manual

Page 18

Advertising
background image

Electrical installation

Connection incremental encoder with TTL level

EDK10203EZ3 DE/EN/FR 4.1

18

l

H1_E_INST−Ink−TTL_en

Connection incremental encoder with TTL level

(

Stop!

Observe the connection voltage of the incremental encoder used!

B

V

CC5 _ E

GND

Z

1
2
3
4
5
6
7
8
9

A

X3

l = max. 50 m

0.14 26

1.0

0.14 26

Æ

AWG

17

A

mm

2

B

Z



A

A

B

Z

B

Z

‚



Incremental encoder with TTL level

‚

Signal flow for CW rotation

ƒ The incremental encoder can be connected with two 5 V complementary signals

electrically offset by 90 °.
– As option, the zero track can be connected.

Assignment of the Sub−D socket

X3

Pin

1

2

3

4

5

6

7

8

9

Signal

B

A

A

V

CC5_E

GND

Z

Z

B

ƒ The connection is to be made as shown in the figure:

– Use cables twisted and shielded in pairs.
– Connect the screen on both ends.
– Observe the cable cross−sections indicated.