Electrical installation – Lenze E82ZAFSC001 User Manual

Page 39

Advertising
background image

Electrical installation

Wiring

6

EDK82ZAFSC DE/EN/FR 5.0

39

l

H2_verdrahtung−INS_Klemmenbeleg

X3/

Signal
type

Function

(Lenze setting: bold print)

Level

(Lenze setting: bold print)

62

Analog
output

Output frequency

0 … +6 V
0 … +10 V

1)

7

GND1,

Reference potential for analog signals

8

Analog
input

Input for actual value or setpoint
Switch over the range with the DIP switch and in C0034:

l

Voltage signal

0 … +5 V
0 … +10 V
−10 … +10 V

2)

l

Current signal

0 … +20 mA
+4 … +20 mA
+4 … +20 mA (open−circuit
monitored)

9

Internal, stabilised DC voltage source for the
setpoint potentiometer

+5.2 V

20

Internal DC voltage supply for control of digital
inputs and outputs

+20 V ±10 % (ref.: X3/7)

28

Digital
inputs

Controller inhibit (CINH)

1 = enable

E1

3)

Activation of JOG frequencies
JOG1 = 20 Hz
JOG2 = 30 Hz
JOG3 = 40 Hz

e1

E2

JOG1

1

0

E2

3)

JOG2

0

1

JOG3

1

1

E3

DC−injection brake (DCB)

1 = DCB

E4

Change of direction of rotation
CW/CCW rotation

E4

CW

0

CCW

1

39

GND2,

Reference potential for digital signals

A1

Digital
output

Ready for operation

l

internal supply:

l

external supply:

0 … +20 V
0 … +24 V

59

DC supply for X3/A1

l

internal (bridge to X3/20):

l

external:

+20 V
+24 V

1)

Output level 0 … +10 V: Adapt offset (C0109/C0422) and gain (C0108/C0420)

2)

Adjust offset (C0026) and gain (C0027) separately for each function module ...
− after replacing the function module or the basic device.
− after loading the Lenze setting.

3)

Frequency input alternatively 0 … 10 kHz single−track or 0 ... 1 kHz two−track, config. via C0425