2.2

Permanently set touch probe inputs

Function library LenzeTpDrv.lib

Introduction

2−2

L

LenzeTpDrv.lib EN 1.2

2.2

Permanently set touch probe inputs

The following inputs have been set as permanent touch probe inputs for the 9300 Servo PLC,
Drive PLC and ECSxA:

Digital input

Source of the angle correction value

9300 Servo PLC

DIGIN_bIn4_b

(X5/E4)

MCTRL_MotorControl

·

Actual motor speed via resolver (X7) or encoder (X8)

DIGIN_bIn5_b

(X5/E5)

DFIN_IO_DigitalFrequency

·

Digital frequency input (X9)

Drive PLC

DIGIN_bIn1_b

(I1)

DFIN_IO_DigitalFrequency

·

Encoder input (X3) extension board 3

ECSxA

DIGIN_bIn1

(X6/DI1)

DFIN_IO_DigitalFrequency

·

Digital frequency input (X8)

DIGIN_bIn2

(X6/DI2)

MCTRL_MotorControl

·

Actual motor speed via resolver (X7) or encoder (X8)

The above inputs are configured via the corresponding codes of the operating system. Detailed
information can be found in the individual PLC Manuals.

2.3

Selecting digital inputs as touch probe inputs

In the DDS control configuration you can select which digital inputs are to receive touch probe
functionality.

Proceed as follows to define a digital input as a touch probe input:

1. Open the PLC Configuration in the register card Resources in the Object Organizer.

2. If the SB DIGITAL_IO has not yet been added to the PLC configuration select Insert

WAdd

subelement

WDIGITAL_IO to add the SB to the PLC configuration.

3. Select the input ( Inputs_DIGIN1...4) to be used as touch probe input.

4. Select Options

WReplace elementWInputs_DIGINx_TP to define the selected input as touch

probe input.
– The command Replace element is also available in the context menu: