Display elements and function keys – Lenze EDK8201BB User Manual

Page 6

Advertising
background image

Display elements and function keys

MA8201BB 2.0

l

- 2 -

Display elements and function keys

S H

P R G

S T P

R U N

P A R 2 0 V L V I M A X D B T E M P

P A R 1

L O A D

S E T

A

%

H z

L O A D

L O A D
L O A D

L O A D

L O A D

g e n e r a t i v e
n o

2 0 %

4 0 %

1 0 0 %

8 0 %

6 0 %

1 6 0 %

L O A D
L O A D
L O A D

l o a d

o v e r l o a d

l o a d

l o a d

l o a d

l o a d

l o a d

l o a d

8201BB operating module

Bargraph display
The last line of the LCD display shows the inverter load:

Key functions
Key

Function

PRG

Change between operating level and code level

SH

Change between code level and parameter level

Increase displayed value

Reduce displayed value

SH +

▲ Scroll up displayed value

SH +

▼ Scroll down displayed value

SH + PRG Save modification (save every parameter individually before disconnecting the controller

from the mains)

STP

Inhibit frequency inverter

RUN

Enable frequency inverter

Status displays
Display

Meaning

OV

Overvoltage

LV

Undervoltage

IMAX

Set current limit exceeded

TEMP

Heatsink temperature immediately before disconnection (

J

max

-10

°C)

PAR1

Parameter set 1 active, PAR1 flashing: programming is possible

PAR2

Parameter set 2 active, PAR2 flashing: programming is possible

SET

Setpoint input via keypad

Five-digit 7-segment display
Display

Meaning

OFF

Frequency inverter inhibited by a LOW signal at terminal 28

STOP

Frequency inverter inhibited (by STP key or quick stop function or field frequencyf

d

= 0Hz)

AS_LC

Autostart lockout, controller will only be enabled after a low-high signal at terminal 28

STO

The parameter is saved

dC_b

DC injection braking active

LU

Undervoltage

SET1

Parameter set 1 is overwritten with the factory setting

SET2

Parameter set 2 is overwritten with the factory setting

rEAd1

Parameter set 1 is overwritten with the operating module data

rEAd2

Parameter set 2 is overwritten with the operating module data

STOE

Parameter sets PAR1 and PAR2 are transmitted to the operating module