4 electrical installation, Important notes, Connection plan – Lenze E82ZM11334B User Manual
Page 37: Electrical installation
![background image](/manuals/566246/37/background.png)
Electrical installation
Important notes
4
EDK82ZM113−002 DE/EN/FR 2.1
37
l
H1_E_INST−−−−(DUMMYSEITEVOR)−−−
4
Electrical installation
Important notes
ƒ Installation must
– always be in accordance with the operating conditions specified in the Technical
data (
^ 31).
– be carried out to EN 60204−1.
ƒ Please observe the following when selecting the cable type:
– The cables used must comply with the approvals required for the application (e. g.
VDE, UL etc.).
– Fuses and cable cross−sections must be dimensioned in accordance with the
specifications in the documentation for the basic device.
ƒ Please observe the following when laying the PE cable:
– The PE connection must comply with EN 61800−5−1.
Connection plan
M
3~
U
U1
V
V1
W
W1
E82ZM...
U
V
W
+UG
+UG
PE
PE
-UG
-UG
PE
E82xVxxxKx
E82ZM−014