16

Parameter reference

16.2

Parameter list | C01230

1002

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01230

C01231

Parameter | Name:

C01230 | Manual jog: Setting

Data type: UNSIGNED_8

Index: 23345

d

= 5B31

h

Settings for "Manual jog" mode

Manual jog

Setting range

(min. hex value | max. hex value)

Lenze setting

0x00

0xFF 0x00 (decimal: 0)

Value is bit-coded: (= bit set)

Info

Bit 0  Breakpoints 1..4 on

"1" ≡ approach of the parameterised breakpoint in

manual jog direction

Bit 1  Time-based start of 2nd speed

"1" ≡ Automatic change-over to second manual speed

after the wating time set in

C01235/1

.

Bit 2  HW limit switch on

"1" ≡ Travel range monitoring via hardware limit switch

is active. The error response can be parameterised in

C00595/1

and

C00595/2

.

Bit 3  SW limit switch on

"1" ≡ Travel range monitoring via parameterised

software limit positions is active. The error response can

be parameterised in

C00595/3

and

C00595/4

.

Bit 4  Reserved
Bit 5  Reserved
Bit 6  Reserved
Bit 7  Position controller off

"1" ≡ Position controller is deactivated. Thus, the

compensation of the following error is switched off.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C01231 | MCK: Manual jog speeds

Data type: INTEGER_32

Index: 23344

d

= 5B30

h

Manual jog speeds

Manual jog

Setting range

(min. value | unit | max. value)

-214748.3647

units/s

214748.3647

Subcodes

Lenze setting

Info

C01231/1

360.0000 units/s

Manual jog: speed 1

• Regular manual speed

C01231/2

720.0000 units/s

Manual jog: Speed 2

• Second manual speed (can be activated via MCK

control word)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Advertising