Oc5: ixt overload, Oc7: motor overcurrent, Ot1: maximum torque reached – Lenze 8400 User Manual

Page 591: Xx.0119.00050, Xx.0123.00007, Xx.0119.00016, Xx.0123.00001, 9diagnostics & error management

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

591

9

Diagnostics & error management

9.10

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

oH5: Brake resistor temperature (X20) tripped [xx.0119.00016]

oC5: Ixt overload [xx.0119.00050]

ot1: Maximum torque reached [xx.0123.00001]

oC7: Motor overcurrent [xx.0123.00007]

Response (Lenze setting printed in bold)

Setting:

C00587/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The brake resistor temperature monitoring at plug X20

has been tripped.

Possible causes:

• The external brake resistor is overheated so that the

thermal contact integrated in the brake resistor has

been switched.

• An open circuit or a loose contact at the connections

mentioned above has occurred.

• Check brake resistor temperature monitoring.

• Provide for sufficient cooling of the external brake

resistor.

• Check terminals for open circuit or loose contact.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The Ixt overload check has tripped.

Possible causes:

• Wrong dimensioning of the device with regard to its

motor load.

• Load cycles are not complied with.

• Check and, if required, correct dimensioning of the

device and the motor load with regard to technical

data.

• Reduce motor load cycles (observe load cycles

according to documentation).

Response (Lenze setting printed in bold)

Setting:

C00608

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device indicates that the maximally possible torque

at the motor shaft has been reached.

•

C00057

displays the current torque.

Reduce motor load.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The maximum current monitoring has tripped.

Check and, if required, correct dimensioning of the load

with regard to the installed device power.

Advertising