Cam type
The cam type is defined through the following numbers:
Entry
Cam type
1
Position cam in positive effective direction
• Switch on and switch off point are defined by positions.
• The cam switches if the direction of the axis is positive (positive speed).
2
Position cam in negative effective direction
• Switch on and switch off point are defined by positions.
• The cam switches if the direction of the axis is negative (negative speed).
3
Position cam with bipolar effective direction
• Switch on and switch off point are defined by positions.
• The cam switches in positive and negative direction of the axis.
11
Time-based cam in positive effective direction
• The cam switches on at the switch on point if the direction of the axis is positive (positive speed).
• After the selected time, the cam switches off.
12
Time-based cam in negative effective direction
• The cam switches on at the switch on point if the direction of the axis is negative (negative
speed).
• After the selected time, the cam switches off.