Loadstar Sensors DS-3000 Digital Load Cell Display & Controller User Manual

Page 43

Advertising
background image

DS-3000U

DS3000 User Guide

Loadstar Sensors, Inc.

Page: 43 / 48

033-01419 Rev. 4

128, with 128 the brightest, and the highest power consumption.

LED xxx

©

Remotely set the LED brightness, replace xxx with your

desired brightness

Summary:

Remotely set current display brightness. This value is R/W.

11.9 ST© (Future Command, Not yet Implemented)

Function:

Sets sleep timeout

Keystrokes:

This command sets the time from the last front panel key-press, until the DS-
3000 goes to sleep. Sleep mode reduces power consumption about 20 - 50%,
which may prolong the operating time when operating in a limited power system,
such as from a battery. Default is disabled. Power save mode shuts off
connected sensors

ST xxx

©

Set the sleep time, in seconds. “0” is disabled.

Summary:

Set the timeout interval until the DS-3000 drops into power save mode.

11.10 RnTPx© (Future Command, Not yet implemented)

Function:

Relay 1 and Relay 2Trigger Points

Keystrokes:

This command remotely sets the programmed trigger points of each relay.

R1TP1 10.1©

R1TP2 5.5 ©

R2TP1 nnnn ©

R2TP2 nnnn ©

Sets Relay 1 threshold 1 to 10.1 of the currently selected unit.

Sets Relay 1 threshold 2, to 5.5 of the currently selected unit.

Sets Relay 2 threshold #1 to nnnn

Sets Relay 2 Threshold #2 to nnnn

Summary:

Allows remote programming of the setpoints of both relay 1 and relay 2 setpoint
values.

11.11 RnTPxT© (Future Command, Not yet implemented)

Function:

Relay trigger point type

Keystrokes:

This command sets the type of trigger point for each of the programmable
thresholds. Choices are “Trigger Above”, or TA, “Trigger Below”,TB, “Reset
Above”, RA, or “Reset Below”, RB.

R1TP1T TA©

R1TP2T TA©

R2TP1T TA©

Set Relay 1, Trigger Point1 to “Trigger Above.”

Set Relay 1, Trigger Point2 to “Trigger Above.”

Set Relay 2, Trigger Point1 to “Trigger Above.”