• Extend and lay out the torch hose package
• Unfasten pressure units and fold out (clamping units and pressure rollers will

automatically flip upwards)

• Unwind welding wire carefully from the wire spool and insert through the wire

connector over the drive roller grooves and the guide pipe into the capillary tube
and Teflon core using guide pipe.

• Press the clamping element with the pressure roller back downwards and fold the

wire units back up again (wire electrode should be in the groove on the drive
roller).

• Set the contact pressure with the adjusting nuts of the pressure unit.
• Press the wire inching button until the wire electrode projects out of the welding

torch.