Marshalltown FCS86 SURFACE SHARK Floor Stripper User Manual

Page 21

Advertising
background image

FCS86 SuRFACE ShARK™ FLooR STRIPPER

PAgE 21

FIguRE 19

6) The Floor Stripper utilizes a factory supplied

extension cord equipped with an integral gFI device.

The gFI device is intended to protect both the

operator and electric motor in the event a ground fault

is developed during operation. The extension cord is

37 foot (11 m) long, fabricated from 12 AWg wire and

incorporates a NEMA 5-15P plug and a NEMA L5-15R

twist lock type receptacle. The twist clock feature

allows the extension cord to be pulled by the Floor

Stripper without becoming disconnected.

BEFORE USE, PROPERLY INSPECT THE

EXTENSION CORD AND WIRING DEVICES

FOR STRUCTURAL INTEGRITY. DO NOT

UTILIZE A CORD WITH A WORN OR CUT

OUTER JACKET MATERIAL. DO NOT

UTILIZE A CORD WITH EXPOSED INNER

WIRES OR INSULATION MATERIAL. DO NOT

UTILIZE A CORD THAT HAS BEEN

REPAIRED WITH ELECTRICAL TAPE. DO

NOT UTILIZE A CORD WITH A CRACKED

AND/OR DAMAGED GFI CASE. USE OF AN

E X T E N S I O N C O R D O F I M P R O P E R

S T R U C T U R A L I N T E G R I T Y A N D / O R

DAMAGED GFI CAN RESULT IN PROPERTY

DAMAGE AND/OR PERSONAL INJURY.

ALL

ELECTRICAL

WIRING,

INCLUDING

EXTENSION CORD GAUGE SIZE AND/OR

LENGTH, MUST BE INSTALLED AND/OR

APPROVED IN ACCORDANCE TO LOCAL

ELECTRICAL CODES AND PRACTICES. AN

IMPROPER WIRING INSTALLATION CAN

RESULT IN PROPERTY DAMAGE AND/OR

PERSONAL INJURY.

7) Determine that the power source receptacle

to be utilized is properly grounded. This can be

accomplished with proper testing equipment and

procedures. If there are any questions regarding

the suitability of a specific power receptacle, contact

your dealer or our Customer Service Department for

assistance bEFoRE utilizing the Floor Stripper.

There is no charge for this service. A qualified

electrician may need to be consulted.

8) If additional extension cord length is required for a

specific job application, an additional extension cord

can be utilized in conjunction with an external gFI.

Plug the receptacle of the additional extension cord into

the factory supplied gFI. Plug the ground fault circuit

interrupter into a seperate power source receptacle.

Connect the extension cord plug into the external gFI.

This configuration will allow any fault over the length of

a defective extension cord to be indicated. Extension

cord gauge size and length must conform to National

Electric Code standards.

FOR MAXIMUM PROTECTION AGAINST A

FAULT, ALWAYS CONFIGURE A GROUND

FAULT CIRCUIT INTERRUPTER TO BE

PLUGGED INTO THE POWER SOURCE

RECEPTACLE. A CONFIGURATION WITH

T H E

G R O U N D

F A U L T

C I R C U I T

INTERRUPTER PLACED BETWEEN THE

FLOOR STRIPPER AND THE POWER SOURCE

RECEPTACLE WILL NOT AFFORD MAXIMUM

P R O T E C T I O N A G A I N S T A P O T E N T I A L

FAULT.

9) Couple the NEMA L5-15R receptacle of the factory

supplied extension cord and the NEMA L5-15P plug

located on the Floor Stripper together. Twist to lock.

FIguRE 20. Connect the gFI to the power source

receptacle. Determine that the reset switch is in its

proper position to activate the gFI.

10) grasp the operator handle with firm gripping. When

starting the electric motor, apply a down force directly

to the operator handle to help reduce the amount of

static machine weight against the work surface. The

blade should remain in contact with the surface. Turn

the oN/oFF switch to the oN position. Reduce the

amount of applied down force on the operator handle

as the electric motor attains its operational speed.

Advertising