Magna-loc, Ul 580 w – Metal Sales Magna-Loc 180 User Manual

Page 10

Advertising
background image

1. Metal Roof Deck Panels* No. 24 MSG min coated steel. Max panel width 18 in.; min 12 in. Rib height 2 in. Panels

continuous over three or more clips (Item 2). The panel flat area may have optional striated or minor ribs placed at various

locations in the panel flat area beginning min of 2 in. from side ribs. The upper flange of the panel rib may be horizontal, or

optionally formed down to produce an angle of 0 to 90° between the vertical segment and the top flange of the rib. Panel end

lap 2 in. min. An end lap back-up plate (Item 2A) to be used at panel end lap. A bead of sealant may be used at panel end lap

and side ribs. Ribs to be seamed with an electric or hand seaming tool to form a flange with a tight hem. Seaming process to

include the upper portion of the panel clips (Item 2) .

METAL SALES MANUFACTURING CORPORATION - “Magna-Loc 16”, “Magna-Loc 18”

2. Roof Deck Fasteners - (Panel Clips) Located at side of panels (Item 1) over substructure (Item 3, 3A, 3B or 3C with max

spacing of 36 in. OC), or plywood decking (Item 7 with max spacing of 36 in. OC). Either of the following:

Fixed Clip (Not Shown) - One piece assembly fabricated from No. 22 MSG min thick steel, 3-1/2 in. wide.

Floating Clip Two piece assembly with a base fabricated from No. 16 MSG min thick steel, 2 in. wide and a tab fabricated

from No. 22 MSG min thick steel, 4-1/4 in. wide.

2A. End Lap Back-Up Plate (Not Shown) - No. 16 MSG min thick coated steel channel, 3 in. wide with two 3/8 in. deep legs.

Max length 74 in. Located under the panel (Item 1) end lap (50 ksi min yield strength).

2B. End Lap Back-Up-Plate (Optional) (Not Shown) - No. 16 MSG min thick coated steel. Width 11, 13 or 19 in., length 7 in.

Two 3/4 in. by 3/4 in. tabs and a 1 in. deep vertical leg located at upslope edge of panel (50 ksi min yield strength).

2C. Roof Deck Fasteners*(Cinch Plate)-(Optional)-(Not Shown) width 1-5/16 in. length 18 in. max. Fabricated from No. 20

MSG min thick stanless steel. Located over end lap.

3. Substructure - (Gypsum Board) (Optional) - Min thick 1/2 in. To be placed on top of either the plywood decking (Item

7) or rigid insulation (Item 5). Combined thickness of the gypsum board and rigid insulation not to exceed 4 in. All joints to be

taped with 2.5 in. wide joint tape.

3A. Substructure - (Plywood) (Optional) - (Not Shown) - Plywood decking, used in lieu of gypsum board (Item 3), to be nom

1/2 in. thick, exposure 1 sheathing, 40/20, CD. Located over rigid insulation (Item 5). Combined thickness of the plywood and

rigid insulation (Item 5) not to exceed 4 in.

3B. Substructure - (OSB) (Optional) - (Not Shown) - OSB decking, used in lieu of gypsum board (Item 3), to be nom 1/2 in.

thick. Located over rigid insulation (Item 5) . Combined thickness of the OSB and rigid insulation not to exceed 4 in.

3C. Substructure - (Bearing Plate) (Optional) - (Not Shown) - Bearing plate to be used in lieu of gypsum board (Item 3) to be

4 by 4 in. by No. 18 MSG min thick coated steel (33 ksi min yield strength). Used under each clip (Item 2) over rigid

insulation (Item 5) only when rigid insulation is located directly under panel (Item 1).

4. Vapor Barrier (Optional) - Single ply, used between the substructure (Items 3, 3A or 3B) or plywood decking (Item 7) and

panels (Item 1). To be min 30 lb roofing felt.

Construction No. 506B

October 16, 2001

Uplift - Class 90

Fire Not Investigated

PML-10

MAGNA-LOC

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

Ul 580 w

ind

U

PlifT

i

nforMaTion

(

ConT

.)

MAGNA-LOC

7

1

6

4

2

1

2

7

6

4

8

Advertising
This manual is related to the following products: