Magna-loc – Metal Sales Magna-Loc 180 User Manual

Page 13

Advertising
background image

PML-13

MAGNA-LOC

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

Slope

Substructure

Clips

Coverage

Length

Fasteners

Availability

GENERAL INFORMATION

Base

Base

Clip

Clip

1

1

/

8

"

Factory Applied Sealant

ATTACHMENT DETAILS

PANEL CLIP

Clip

ALLOWABLE UNIFORM LIVE LOADS PSF

(3 or More Equal Spans)

1’ 2’ 2.5’ 3' 4’ 5’ 1’ 2’ 2.5’ 3’ 4’ 5’

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

16”

50

18”

50

24

Ga.

24

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

1.24
1.21

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

0.1403 0.0772 0.0720 0.0656

1166 352 232 164 94 60 146 119 105 92 64 37

0.0691

0.0320

0.0640

0.0583 1000

250 160 111 63 40 115 95 85 75 46 30

Inward (Gravity / Deflection)

Load

Outward Uplift (Stress)

Load

The minimum recommended slope for the Magna-Loc 180

roof panel is 1/2:12.

Magna-Loc 180 is designed to be utilized over open

structural framing or a solid substrate.

Clip spacing is based upon the spacing of structural fram-

ing members and loading requirements.

Magna-Loc 180 panels are available in a 2" seam height

with a 16" or 18" width coverage.

Minimum factory cut length is 5'-0" (with striations), 7'-0"

(without striations). Maximum recommended panel

length is 45'-0". Longer panels require additional con-

sideration in packaging, shipping, and erection. Please

consult Metal Sales for recommendations.

The fastener selection guide should be consulted for

choosing the proper fastener for specific applications.

Quantity and type of fastener must meet necessary load-

ing and code requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of

the panel at or near the point of attachment.

Finishes: Acrylic Coated Galvalume

®

or various Kynar 500

(PVDF) colors.

Gauge: 24ga

1. Theoretical section properties have been calculated per AISI 2001 “Specification for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are

effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear, deflection, and ASTM 1592

testing. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or

fasteners/support connection and panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase in uplift.

Magna-Loc 180 Panel

BEFORE SEAMING

AFTER SEAMING

Clip Fastener

Factory Applied Sealant

Clip

Magna-Loc 180 Panel

Clip Fastener

Striated

Factory Applied Sealant

2"

16" or 18" Coverage

Pencil Ribs

Factory Applied Sealant

2"

16" or 18" Coverage

Magna-Loc 180

s

eCTion

P

roPerTies

& g

eneral

i

nforMaTion