Magna-loc – Metal Sales Magna-Loc 180 User Manual

Page 12

Advertising
background image

PML-12

MAGNA-LOC

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

s

eCTion

P

roPerTies

& g

eneral

i

nforMaTion

Magna-Loc

Slope

Substructure

Clips

Coverage

Length

Fasteners

Availability

GENERAL INFORMATION

Base

Base

Clip

Clip

1

1

/

8

"

Clip

Magna-Loc

Panel

Factory Applied

Sealant

Factory Applied

Sealant

ATTACHMENT DETAILS

PANEL CLIP

The minimum recommended slope for the Magna-Loc

roof panel is 1/2:12.

Magna-Loc is designed to be utilized over open structural

framing or a solid substrate.

Clip spacing is based upon the spacing of structural

framing members and loading requirements.

Magna-Loc panels are available in a 2" seam height with

a 16" or 18" width coverage.

Minimum factory cut length is 5'-0" (with striations), 7'-0"

(without striations). Maximum recommended panel

length is 45'-0". Longer panels require additional

consideration in packaging, shipping, and erection.

Please consult Metal Sales for recommendations.

The fastener selection guide should be consulted for

choosing the proper fastener for specific applications.

Quantity and type of fastener must meet necessary

loading and code requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of

the panel at or near the point of attachment.

Finishes: Acrylic Coated Galvalume

®

and

PVDF (Kynar 500).

Gauges: 24 ga standard, 22 ga and 20 ga optional

BEFORE SEAMING

AFTER SEAMING

Clip

Magna-Loc

Panel

1. Theoretical section properties have been calculated per AISI 2001 “Specification for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are

effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear, deflection, and ASTM 1592

testing for 24 ga and 22 ga. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or

fasteners/support connection or testing for 20 ga and panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase in uplift.

SECTION PROPERTIES

ALLOWABLE UNIFORM LOADS psf

(3 or More Equal Spans)

Ga. Width

in

Yield

ksi

Weight

psf

Top In Compression Bottom In Compression

Inward

Load

Outward

Load

Ixx

in

4

/ft

Sxx

in

3

/ft

Ixx

in

4

/ft

Sxx

in

3

/ft

2.5' 3' 3.5' 4' 4.5' 5' 2.5' 3' 3.5' 4' 4.5' 5'

24

16"

50

1.25

0.1785

0.1013

0.0855

0.0754

161 126 101 82 68 57 111 99 87 75 63 51

22

16"

50

1.63

0.2468

0.1419

0.1178

0.1066

257 197 155 125 103 86 119 110 101 92 83 74

20

16"

33

2.02

0.3165

0.1831

0.1643

0.1474

252 189 147 117 93 76 392 283 213 166 133 109

24

18"

50

1.21

0.1620

0.0900

0.0760

0.0669

144 112 89 73 61 51

68 62 56 50 43 37

22

18"

50

1.58

0.2233

0.1255

0.1047

0.0947

233 176 138 111 91 74

78 73 68 62 57 52

20

18"

33

1.96

0.2893

0.1640

0.1460

0.1310

224 168 131 104 83 67 350 253 191 149 119 97

Factory Applied Sealant

Striated

2"

16" or 18" Coverage

Factory Applied Sealant

2"

16" or 18" Coverage

Pencil Ribs