Magna-loc, Caution – Metal Sales Magna-Loc 180 User Manual

Page 18

Advertising
background image

PML-18

MAGNA-LOC

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

d

esign

/ i

nsTallaTion

C

onsideraTions

(

ConT

)

Note: When panels are installed from left to right, electric seamer operates from ridge to eave.

CAUTION

Do not run the seamer off the end of the panel. If the seamer is run off the end of the roof it

could cause injury to personnel and damage the roof or the seamer (see seamer instructions

enclosed in the case for additional information about the proper handling of the seamer).

Factory applied sealant

Clip

Panel

Fastener

8"

Hand Crimper

Seaming direction

SEAMING PANELS

(CONT.)

Steps:

1. To start seaming, first hand crimp 8” of seam at eave, endlap, and ridge locations only.

DO NOT hand crimp at clip locations.

2. Position mechanical seamer over hand crimped roof seam at ridge location so that the levers are on the same side of the

seam that is to be crimped by the mechanical seamer.

3. Engage roller levers in the following order: #1, #2, #3, #4, and then the precrimp roller lever. Precrimp lever may need to

be held down to avoid scratching of panel.

4. Prior to running seamer, check to make sure that Magna-Loc panels are fully engaged along the entire run of the panel.

Small c-clamps may be required on the horizontal portion of the seam to hold panel seam engaged while seaming.

5. Turn on the power to seamer and walk with the seamer as it seams the panel. Stop the seamer in the first few feet to

ensure proper seam is being achieved. Turn the mechanical seamer off before the hand crimped endlap or eave portion

of

the panel. If Magna-Loc roof panels have been endlaped, mechanical seamer must be stopped, moved, and restarted

over

the hand crimped area of the endlap. Remaining seam between hand crimped portion and mechanically seamed

portion may

have to be hand crimped for continuous tight seam.

6. At the end of the first run, remove mechanical seamer and return to step #1 for remaining panels.

7. At completion of seaming, repack tool and return to Seamer Tools, Inc. 8265 Highway 178, Olive Branch, MS 38654.

Phone No. 662.895.1222, Fax No. 662.890.4775.

Cee Clamp

Clip