3.4.0 Series 111 Accumulator Specifications

The following tables list the specifications for the Series 111 Accumulators.

Product Specifications

Model 111.12C

Model 111.11B

Parameter

138 MPa (20,000 psi)

83 MPa (12,000 psi)

Minimum burst pressure

22 MPa (3200 psi)

21 MPa (3000 psi)

Rated fatigue pressure

–40°C to 93.3°C (–40°F to 200°F)

Operating temperature

Petroleum-based hydraulic fluid. Contact MTS for use with other fluids.

Hydraulic fluid

Dry nitrogen

Dry nitrogen

Note:

Specifications are subject to change without notice. Contact MTS Systems Corporation for verification
of specifications critical to your needs.

Capacity, Dimension, and Weight

Maxp

Hydraulic

Fluid Port

Connection

B

A

Length

Nitrogen Gas

Capacity

Model

*

kg (lbs)

cm

(in.)

cm (in.)

cm (in.)

4.26
(9.4)

12 SAE

(1-1/16-12

UNF-2B)

6.35

(2.5)

7.87 (3.1)

15.54 (6.12)

82 cm

3

(5 in.

3

)

111.11B-01

*

The models listed in this table are considered standard models. Other models may be manufactured with
different capacities, lengths, or hydraulic fluid port connections than listed here. Contact MTS Systems
Corporation for information on nonstandard models.

See the related cross-section figures.

Standard pressure series (Code 61).