0 series 111 accumulator installation procedure – MTS Series 111 Accumulator User Manual

Page 27

Advertising
background image

Description

Item

Flange Mounting Bolt

1

Flange Mounting O-rings

2

Accumulator Mounting Bolts (4)

3

5.1.1.0 Series 111 Accumulator Installation Procedure

Required equipment

The following equipment is required for accumulator installation:

Open-end wrench and strap wrench (for the Model 111.11B)

Hex key set and torque wrench (for the Model 111.12C)

Note:

When installing a replacement accumulator into an existing system, the replacement accumulator
should be precharged to the same pressure level as the accumulator being removed. Be sure that
this precharge level is recorded on the label of the replacement accumulator.

1. Mount the accumulator in the system after lubricating the mounting O-ring seal(s). Note the O-ring seal

configuration.

For the Model 111.11B Accumulator Thread the unit onto the boss adapter fitting and securely tighten
it with a strap wrench.

For the Model 111.12C Accumulator Lubricate and torque the four mounting bolts in increments
(according to the pattern shown in the “Mounting Configurations” figure) to a final torque of 108 N·m
(80 lbf-ft).

2. Check the accumulator precharge pressure as described in the related procedure.

Series 111 Accumulator Product Information 27

5.0 Installation

Advertising