Installing a collet for a flat specimen, Installing a collet for a flat specimen 56 – MTS Series 646 Hydraulic Collet Grips User Manual

Page 56

Advertising
background image

Series 646 Hydraulic Collet Grips

56

Operation

Installing a Collet for a Flat Specimen

To install a collet assembly for a flat specimen into the grip housing:

Flat Collet

1. Ensure that the grips are in the release condition and that hydraulic pressure

is turned off.

2. Clean the specimen contacting surfaces of the collet with acetone or any

other volatile solvent that does not leave a residue.

3. Apply a thin layer of Molykote G·n paste (part of the grip service kit) to the

threaded surfaces of the collets.

4. Position the rubber platen between the two collet halves.

5. Use a spanner wrench to thread the collet assembly into the grip housing

until the top surface of the collet is flush with the top surface of the grip
housing.

6. Adjust the collet assembly as necessary until the alignment mark on the

collet corresponds to the alignment mark on the grip housing.

7. Ensure that the specimen mounting openings are parallel between the upper

and lower grip. If they are not properly aligned, use a spanner wrench and
rotate the actuator rod to achieve proper alignment.

For axial/torsional systems, it might be necessary to rotate the actuator.

Alignment Mark

Spanner Wrench Holes

Coat the threads on
the collet with
Molykote G-n paste

Rubber Platen

Top View

Cutaway
Side View

Advertising