Specifications, Specifications 10 – MTS Model 512-14 Hydraulic Power Unit User Manual

Page 10

Advertising
background image

512.14 Hydraulic Power Unit

10

Specifications

Introduction

Specifications

Parameter

Specification

Environmental

Operating temperature
(ambient air)

Heat load

*

Noise rating

at 1 m

18–40°C (65–104°F)

1061 kcal/hr (4200 BTU/hr)

74 dB (A)

Pump

Flow capacity

Motor rating

Operating voltage

12.5 lpm (3.3 gpm) @ 50 Hz
15.1 lpm (4 gpm) @ 60 Hz

5.6 kW (7.5 hp)

208 V (AC) @ 24.2 A, 3 phase
230 V (AC) @ 22.0 A, 3 phase
460 V (AC) @ 11.0 A, 3 phase

Hydraulic fluid

Nominal temperature

Filtration (microns)

Reservoir capacity

Maximum pressure

Mobil DTE 25

®

or Shell Tellus

®

46 AW

63°C (145°F)

3 microns absolute

57 liters (15 gallons)

20.7 MPa (3000 psi)

Heat exchanger

Flow requirements

Water pressure
(differential)

Max input pressure

Cooling

Water hose

Water cooled or air cooled

13 lpm @ 21°C (3.5 gpm @ 70°F)

0.2 MPa (30 psi)

1 MPa (150 psi)

4892 Kcal/hr (19,410 BTU/hr)

12.7 mm (0.5 in)—inside diameter

Hydraulic connections

Pressure
Return
Drain

each requires a 37° flare

-8
-8
-6

Weight

115 kg (250 lb)

*

Specification is for 60 Hz operation.

Free field value [74 db. Your readings may be up to 10 db (A) more.

Advertising