Installation, Installation 13 – MTS Model 512-14 Hydraulic Power Unit User Manual

Page 13

Advertising
background image

512.14 Hydraulic Power Unit

Installation

13

Installation

This section describes how to install a Model 512.14 Hydraulic Power Unit.

Note

The HPU is designed for indoor use. The HPU should be stored and
installed indoors.

1. Position the hydraulic power unit.

Determine where to put the HPU. Since it is connected to the other
hydraulic equipment through hydraulic lines, the HPU can be located
remotely. Considerations include:

The air cooled HPU must be located where adequate air movement for
cooling can occur.

The water cooled HPU requires a source of water.

The HPU can be moved by a forklift, pallet jack or dolly.

The HPU produces 74 dB of sound pressure level in a free field acoustic
environment.

The base of the HPU has four holes that may be used to secure the unit in
place.

Connection Locations (Top View)

Drain Line Connection

Emergency Stop

Connection

Cooling Water In

Return Line Connection

Pressure Line Connection

Cooling Water Out

Water Valve

Advertising