Maintenance

Spare parts

Parts that are specified in the maintenance procedures of this section can be
obtained from MTS Systems Corporation. See “Contact information” on the back
of the title page to order spare parts.

Verify functionality of
HPU interlocks

Every 1000 hours or 6 months

Contact MTS Systems Corporation.

Lubricate pump motor

Every 1000 hours or 6 months

Perform

“Lubricating the Motor”

on page 39.

Check motor overload
functionality

Every 1000 hours or 6 months

Contact MTS Systems Corporation.

Verify proper operation of
hydraulic valves

Every 1000 hours or 6 months

Contact MTS Systems Corporation.

Conduct a hydraulic fluid
analysis

Every 6 months or sooner if duty
is severe

.

Obtain a sample and submit it for analysis.

Most oil or other qualified companies can
analyze hydraulic fluid or consult MTS

Systems Corporation.

Perform

“Sampling the Hydraulic Fluid”

on

page 32.

Replace hydraulic fluid

Every 6 months or sooner if fluid
analysis is not to specifications.

Perform

“Replacing the Hydraulic Fluid”

on

page 36.

Conduct internal
inspection of heat
exchanger

*,

Yearly, or every 2000 hours

Look for signs of fouling or corrosion,

conduct chemical or mechanical internal
cleaning as inspection warrants.

Consult the Heat Exchanger Care Guide for
more information.

Check case drain flow of
hydraulic pump

Yearly, or every 2000 hours

Contact MTS Systems Corporation.

Replace heat exchanger

Every 3 years or 5,000 hours

Replace as inspection warrants. Contact MTS

Systems Corporation for special training.

Replace motor bearings

Every 3 years or 5,000 hours

Contact MTS Systems Corporation.

Replace hydraulic hoses,
motors, pumps

Every 5 years or 10,000 hours

Replace as inspection warrants. Hydraulic

pumps may be rebuilt or replaced as required

by inspection. Motors may be rewound or
replaced as required by inspection. Contact

MTS Systems Corporation for special

training.

* See the MTS Heat Exchanger Care Guide (part number 015-164-000).
† Special training required. Contact MTS Systems Corporation.
‡ See the MTS Fluid Care Guide (part number 050-000-536).

Maintenance Schedule (part 2 of 2)

What to Do

When to Do It

How to Do It