MTS Multi-Pump Control Manager User Manual

Page 21

Advertising
background image

System

Multi-Pump Control Manager

Operation

21

Item

Name

Description

1

System gauges: Flow/Pressure/
Temperature

System gauges. The parameters of these gauges are
determined by settings on the MPCM Setup screen.

Flow - LPM or GPM. Gauge full scale is determined by
the total number of modules present. Green range is
determined by the total number of modules running in the
system. Gauge reading is the current flow if a flow meter
is present on all HPU(s). If a flow meter is not present,
the gauge reading is the flow demand in the Auto mode.
If flow meters are not present and the system is being
operated in manual mode, gauge will read zero.

Pressure (optional)- MPa or PSI. Full scale reading is
determined by values set on the Setup screen. Gauge is
not shown if sensor is not present and enabled.

Temperature (optional)- °C or °F. Full scale reading is
determined by values set on the Setup screen. Gauge is
not shown if sensor is not present and enabled.

Red/green/yellow ranges are normalized based on system
setup.

2

HPU gauges: Flow (optional)

Flow - LPM or GPM. Gauge full scale is determined by
the number of modules present on that HPU. Green
gauge range is determined by the number of modules
running on that HPU.

Gauge is configured in the Setup page on the HPU.
Gauge is not shown if flow meter is not present and
enabled.

3

HPU gauges: Pressure/
Temperature/Level

Pressure - MPa or PSI. Gauge reading is determined by
HPU’s sensor.

Temperature - °C or °F. Gauge reading is determined by
HPU’s sensor.

Red/green/yellow ranges are normalized based on HPU
setup.

Level - status bar. Colored area indicates fluid level
relative to full capacity (in eights) which is represented
by the overall bar:

flashing red - 0/8
yellow - 1/8
green - 2/8 to 7/8
flashing red - 8/8