Status Screen

Remote Human Machine Interface

Operation

19

Oil Level

Indicator. Used to indicate if the hydraulic fluid level is within
acceptable limits.

Oil Level - gray (OK): Indicates the hydraulic fluid level is within
acceptable limits.

Oil Level - red (fault): Indicates the hydraulic fluid level is not
within acceptable limits and an interlock is active.

Oil Temp

Indicator. Used to indicate if the hydraulic fluid temperature is
within acceptable limits.

Oil Temp - gray (OK): Indicates the hydraulic fluid temperature is
within acceptable limits.

Oil Temp - yellow (alarm): Allows you to set up an indication that
the hydraulic fluid is above normal but not hot enough to shut
down the system. The value is set at the HPU HMI.

Oil Temp Fault - red: Indicates the hydraulic fluid temperature is
not within acceptable limits and an interlock is active. Acceptable
limits are 55°C +/- 3°C (121°F +/- 5°F).

Return Filter

Indicator. Used to indicate if the return filter is within acceptable
limits.

Return Filter - gray (OK): Indicates the contamination in the
return filter is within acceptable limits.

Return Filter - yellow (alarm): Indicates the contamination in the
return filter is not within acceptable limits. This state will not
generate an active interlock, but alerts the user that the filter
requires maintenance.

Return Filter - red (fault): The HPU cannot be started with an
active return filter warning

Pressure Filter (optional)

Indicator. Used to indicate if the pressure filter is within
acceptable limits.

Press Filter - gray (OK): Indicates the contamination in the
pressure filter is within acceptable limits.

Press Filter - yellow (alarm): Indicates the contamination in the
pressure filter is not within acceptable limits. This state will not
generate an active interlock, but alerts the user that the filter
requires maintenance.

Press Filter - red (fault): The HPU cannot be started with an active
pressure filter warning.

Module #N

Indicator. Used as an identifier for the Status and Hours
parameters.

Module - blue-green: Label.

#N - blue-green: #1 is associated with pump module 1. #2 is
associated with pump module 2. Etc.