Auto Setup

Remote Human Machine Interface

Operation

23

ROD On Delay (sec)

ROD On Delay (sec) - blue-green: Indicator used as a label for the
pushbutton switch below it.

ROD On Delay numeric display - pushbutton/indicator - gray:
Used to set the delay in seconds. The flow must be at or above the
trigger level for this amount of time before the next pump motor
turns on. Push the button to display the numeric keypad. With the
keypad displayed, use the number keys to define the desired delay
then press Enter to set the value and return to the Auto Setup
screen.

Minimum time for this setting is 1 second.

ROD Off Delay (sec)

ROD Off Delay (sec) - blue-green: Indicator used as a label for
the pushbutton switch below it.

ROD Off Delay numeric display - pushbutton/indicator - gray:
Used to set the delay in seconds. The flow must be below the
trigger level for this amount of time before the next pump motor
turns off. Push the button to display numeric keypad. With the
keypad displayed, use the number keys to define the desired delay
then press Enter to set the value and return to the Auto Setup
screen.

Minimum time for this setting is 10 minutes. This is intended to
prevent constant pump motor cycling when flow demand is
fluctuating slightly above and below the trigger level.

Rated Flow per Module (units)

Rated Flow per Module (units) - blue-green: Indicator used as a
label for the pushbutton switch below it.

Rated Flow per Module numeric display - pushbutton/indicator -
gray: Used to set the full flow rating of the pump modules. Push
the button to display numeric keypad. With the keypad displayed,
use the number keys to define the full flow rating then press Enter
to set the value and return to the Auto Setup screen.

Flow Meter Present/Flow Meter Not
Present

Pushbutton/Indicator. Pushbutton used to define if a flow meter is
present or not. Pressing the button alternates between the states.

Flow Meter Not Present- gray: In this state, there is no flow meter
and the ROD option can not be used. However, the Auto feature
can be used; see

“Auto”

on page 16.

Flow Meter Present - black: In this state, the flow meter is present
and the ROD option (if purchased) can be used.

Flow Display In GPM/Flow Display in
LPM

Pushbutton/Indicator. Pushbutton used to define which units are
displayed for hydraulic fluid flow. Pressing the button alternates
between the states.

Flow Display in GPM - gray.

Flow Display in LPM - gray.

Control

Descriptions