Inelastic Strain Minimum-Maximum Table

The Inelastic Strain Min Max table contains the measured and calculated minimum and maximum inelastic
strain values. The table also contains the measured plastic strain range.

Modulus by Cycles Table

The Modulus by Cycles table contains these values:

•

Calculated cycle modulus

•

Calculated loading modulus

•

Calculated unloading modulus

•

Hysteresis area

•

Calculated first cycle modulus

Peak-Valley Data by Cycles Table

The Peak Valley Data by Cycles table contains the peak and valley values of each cycle:

•

Load

•

Stress

•

Strain

•

Displacement

Cycle Variables

The Cycle Variables table contains information about cycle variables. If the value is modified during analysis,
a check mark appears in the Modified column and the value in the Value column differs from the value in the
Original Value column. Modified values do not replace, change, or remove original test results data.

Variable Table

The Variable table contains information about test variables. If the value is modified during analysis, a check
mark appears in the Modified column and the value in the Value column differs from the value in the Original
Value column. The table includes:

•

Category

•

Display Name

•

Value

•

Unit

•

Modified

•

Original Value

•

Dimension

•

Array

•

Calculation

Modified values do not replace, change, or remove original test results data.

50 MTS TestSuite

6.0 ASTM Low-Cycle Fatigue (LCF) Elevated Temperature Template