104
Cable Configurations
Installing the Transducer
Termination Jumper
The following jumper plug (MTS p/n 510743-01) is used to terminate a chain of
SWIFT TIs using multidrop RS-485 communication. It plugs into connector
COMM OUT of the last SWIFT TI in the communications chain.
1
2
3
4
5
6
7
8
+TX
TX
+RX
+TERMINATE
TERMINATE
TERMINATE
To COMM OUT
of SWIFT TI
Module
Termination Jumper
(MTS p/n 510743-01)