Specifications, Specifications 25 – MTS SWIFT 40 Sensor User Manual

Page 25

Advertising
background image

Specifications

SWIFT 40 Sensors

Hardware Overview

25

Specifications

SWIFT 40 Transducer Performance

P

ARAMETER

S

PECIFICATION

Use

SWIFT 40 A (aluminum) for

SWIFT 40 T (titanium) for

low weight, high sensitivity

high fatigue life, durability

Maximum usable rpm

2,200

Maximum speed

240 kph (150 mph)

fits rim size (usable range)

13–17 inch

*

*

A special flange configuration is required for a 13 inch wheel. Larger diameter rims can be used, providing
that overall clearance from brake calipers and suspension components is maintained.

Maximum hub bolt circle diameter
accommodates M12 or 1/2 inch studs

170.5 mm (6.713 in)

Input voltage required

10–17 VDC

Input power required per transducer

30 W maximum (22 W typical)

Output voltage ± full scale calibrated load

±10 V

† Load impedance >1 k

Ω

; 0.01 µF (maximum) load capacitance.

SAE J328 rated load capacity

Aluminum

Titanium

12 kN (2,700 lbf)

22.7 kN (5,100 lbf)

Standard Maximum Calibrated Load Rating

‡ The actual calibrated range may be different based on individual customer requirements. Consult the

calibration range sheet that accompanies each transducer for the correct calibration range.

Longitudinal force (Fx)

±40 kN (±8,990 lbf)

±60 kN (±13,490 lbf)

Lateral force range (Fy)

±30 kN (±6,745 lbf)

±45 kN (±10,115 lbf)

Vertical force range (Fz)

±40 kN (±8,990 lbf)

±60 kN (±13,490 lbf)

Overturning moment (Mx)

±9 kN•m (±79,655 lbf•in)

±15 kN•m (±132,760 lbf•in)

Driving/braking moment (My)

±13 kN•m (±115,060 lbf•in)

±20 kN•m (±117,015 lbf•in)

Steering moment (Mz)

±9 kN•m (±79,655 lbf•in)

±15 kN•m (±132,760 lbf•in)

Resolution (analog system)

Infinite

Noise level (peak-to-peak 0-500 Hz)

20 N (4.5 lbf)

30 N (6.7 lbf)

Performance accuracy

Nonlinearity

1.0% full scale

Hysteresis

0.5% full scale

Modulation

§

§ Typical value on most steel rims. Aluminum rims typically have slightly higher modulation, but at a lower

added weight.

≤3.0% reading

Cross talk

#

# Each SWIFT sensor is calibrated on an MTS calibration machine. MTS provides complete documentation

of calibration values for each SWIFT unit

1.5% full scale

Maximum operating temperature

Low level amplifiers

Transducer interface

70°C (158°F)

50°C (122°F)

Advertising