gaC9.7HZ 60 HZ geNeRaTOR • OpeRaTiON aNd paRTs maNual — Rev. #2 (03/31/10) — page 17

COMpOnents (generatOr)

Figure 3. Generator Components

1.

gFCi Breakers (2) – These single pole circuit breakers

(120V, 15 amps) protect the GFCI receptacles. When

starting the generator always have these circuit

breakers placed in the "

OFF" position.

2.

30 amp Breaker – Single pole 30 amp circuit breaker

protects the 120V twist-lock receptacle. When starting

the generator always have this circuit breaker placed

in the "

OFF" position.

3.

20 amp Breaker – 2-pole 20 amp circuit breaker

protects the 240V twist-lock receptacle. When starting

the generator always have this circuit breaker placed

in the "

OFF" position.

4.

30 amp Breaker – 2-pole 30 amp circuit breaker

protects the 120/240V twist-lock receptacle. When

starting the generator always have this circuit breaker

placed in the "

OFF" position.

5.

aC-voltmeter – This voltmeter indicates (with a

mark) the rated 60 Hz (single-phase) output voltage.

In addition the voltmeter can also be used as a

diagnostic tool. If the voltmeter indicator (needle) is

below the rated voltage, engine problems may exist

(low/high RPM's). To prevent damage to the generator

or power tools turn the generator

OFF and consult your

authorized Multiquip service dealer.

6.

idle Control switch – The generator is provided with

an automatic idle control device for noise suppression

and reduced fuel consumption.

The automatic idle control automatically engages under

a no-load condition. With the automatic idle control

switched “

ON”, the engine revolutions will automatically

drop to about 2600 rpm (low-speed operation) within

3 seconds after the load stops. When the operation is

resumed, the engine speed is automatically increased

to about 3600 rpm (high-speed operation) as soon as

the load is connected.

7.

Operation switch – Place switch in the "ON" position

(up) for normal operation. To turn-off the generator,

place the operation switch in the "

OFF" position (down).

8.

start Button – Press this pushbutton switch to start

the generator.

9.

main Breaker – 2-pole 35 amp circuit breaker protects

the generator from short circuiting or overloading.

When starting the generator always have this circuit

breaker placed in the "

OFF" position.

10.

120/240v Output Receptacle – NEMA L14-30R twist-

lock receptacle will provide 120/240V, 30 amps, 60 Hz.

11.

240v Output Receptacle – NEMA L6-20R twist-lock

receptacle will provide 240V, 20 amps, 60 Hz.

12.

120v Output Receptacle – NEMA L5-30R twist-lock

receptacle will provide 120V, 30 amps, 60 Hz.

13.

gFCi duplex Receptacle – NEMA 5-15R, GFCI

receptacle will provide 120V, 15 amps.

14.

ground lug – This ground connection point should be

connect to a good earth ground (ground rod).