gaC9.7HZ 60 HZ geNeRaTOR • OpeRaTiON aNd paRTs maNual — Rev. #2 (03/31/10) — page 27

MaintenanCe

maintenance

Perform the scheduled maintenance procedures as defined

by Table 5 and below:

daily

„

Thoroughly remove dirt and oil from the engine and

control area. Clean or replace the air cleaner elements

as necessary. Check and retighten all fasteners as

necessary.

Weekly

„

Remove the fuel filter cap and clean the inside of the

fuel tank.

„

Remove or clean the filter at the bottom of the tank.

„

Remove and clean the spark plug (Figure 29), then adjust

the spark gap to 0.024 ~0.028 inch (0.6~0.7 mm). This

unit has electronic ignition, which requires no adjustments.

Figure 29. Spark Plug Gap

engine Oil and Filter

1. Drain engine oil when the oil is warm as shown in

Figure 30.

2. Remove oil drain bolt and sealing washer and allow

engine oil to drain into a suitable container.

Figure 30. Draining Engine Oil

3. Use an oil filter socket tool and remove oil filter as

shown in Figure 31

Figure 31. Oil Filter Removal

4. Clean oil filter mounting base, and coat oil filter seal

(Figure 31) with clen engine oil.

5. Screw on new oil filter by hand until seal contacts the

filter mounting base. Using an oil filter socket tool,

tighten filter and additional 7/8-inch turn. Tighten filter

to 16ft-lbs. (22 N.m).

6. Install drain bolt with sealing washer and tighten

securely.

7. Replace engine oil with recommended type oil as listed

in Table 4. For engine oil capacity, see Table 2 (engine

specifications ). Fill to upper limit as shown in Figure 30.