Operation – Multiquip GAC-9.7HZ User Manual

Page 22

Advertising
background image

page 22 — gaC9.7HZ 60 HZ geNeRaTOR• OpeRaTiON aNd paRTs maNual — Rev. #2 (03/31/10)

OperatiOn

This section is intended to assist the operator with the initial

start-up of the portable generator. It is extremely important

that this section be read carefully before attempting to use

the generator in the field.

Before starting the engine

1. Be sure to disconnect all electrical loads from the

generator prior to starting the engine.

2.

NeveR start the engine with the main circuit breaker

in the

ON position. Always place circuit breaker (Figure 11)

in the

OFF position before starting.

Figure 11. Main Circuit Breaker (OFF)

3.

NeveR start the engine with the GFCI or AUX. circuit

breakers in the

ON position. Always place these circuit

breakers (Figure 12) in the

OFF position before starting

the engine.

Figure 12. GFCI/AUX. Circuit Breakers (OFF)

starting the engine

4. Place the choke knob (Figure 13) in the

ClOsed

position if starting a cold engine.

Figure 13. Choke Knob

5. Place the choke knob (Figure 13) in the

OpeN position

if starting a warm engine or the temperature is warm.

6. Place the generator's operation switch (Figure 14) in

the

ON position.

Figure 14. Operation Switch (ON)

7. Press the generator's pushbutton start switch (Figure

15) and listen for the engine to start. If the battery is

not installed proceed to step 6.

Figure 15. Start Pushbutton Switch

8. Grasp the starter grip (Figure 16) and slowly pull it out.

The resistance becomes the hardest at a certain

position, corresponding to the compression point. Pull

the starter grip briskly and smoothly for starting.

Figure 16. Starter Grip

9. If the engine has started, slowly return the choke lever

(Figure 13) to the

OpeN position. If the engine has not

started repeat steps 1 through 8.

10. Before the generator is placed into operation, run the

engine for 3-5 minutes. Check for abnormal smells,

fuel leaks, and noises that would associate with lose

components.

NOTICE

dO NOT pull the starter rope all the way to the end.
dO NOT release the starter rope after pulling. Allow it

to rewind as soon as possible..