DCA-45USI — GENERATOR START-UP PROCEDURE

Figure 51. Engine Tachometer

14. The tachometer (Figure 51) will indicate the speed of

the engine when the generator is operating. Under normal
operating conditions this speed is approximately 1800
RPM’s.

15. Turn the

main, GFCI, and aux. circuit breakers to the

ON position (Figure 52).

13. The coolant temperature gauge (Figure 50) will indicate

the coolant temperature. Under normal operating
conditions the coolant temperature is between 165 and
203° degrees Fahrenheit.

Figure 50. Coolant Temperature Gauge

16. Observe the generator's ammeter (Figure 53) and verify

it reads the anticipated amount of current with respect
to the load. The ammeter will only display a current
reading if the load is in use.

Figure 53. Ammeter (Load)

Figure 52. Main, AUX. and GFCI

Circuit Breakers (ON)

12. The engine oil pressure gauge (Figure 49) will indicate

the oil pressure of the engine. Under normal operating
conditions the oil pressure is approximately

Figure 49. Oil Pressure Gauge

17. The generator will run until manually stopped or an

abnormal condition occurs.