Utl series, Assembly instruction, Technical information – Northern Connectors Souriau UTL Series Push-Pull Connectors User Manual

Page 33: Utl stripping dimensions, Assembly

Advertising
background image

33

© 2012 – SOURIAU

• 1 - Female insulator: Strip external cable sheath, adjust ground cable length
• 2 - Male insulator: Strip external cable sheath, adjust signal cable lengths
• 3 - Crimp contacts
• 4 - Place the lubrifi cant on the contact orings
• 5 - Place all the contacts inside the corresponding cavities in the same time
• 6 - Manually push each contact, or use specifi c tools, until audible click.
Check each contact rétention, with a traction with two fi ngers

UTL stripping dimensions

* see page 31

UTL0103G1P - UTL6103G1P -

UTL7103G1P - UTL1103G1P

UTL0103G1S - UTL6103G1S -

UTL7103G1S - UTL1103G1S

Ground contact must be different compared to the others.

L*

L*

30.1mm

32.1mm

Phase lines - male contacts

Phase lines - male contacts

Ground line -

female contact

Ground line - female contact

25mm

25mm

Assembly instruction

UTL Series

Technical information

• Strip wires, crimp contacts
• Insert contacts into connector cavities (insert manually or use tool RTM2

0

5 crimp contacts)

• Place receptacle in the panel cut-out (see dimension page 15)
• Secure receptacle with M3 screws (not supplied), torque 0.7 N.m maxi

Panel

Panel

Receptacle fl ange

Pa

Pa

UTL

0

assembly

(mounting suggestion)

T

echnical information