Technical information

Evaluation kit

The boot is semi-fl exible and heat-shrinkable with a moldable adhesive inner lining.

• 1 - Place the heat shrink boot over the cable
• 2 - Strip the cable jacket (see page 33)
• 3 - Strip the individual wires (see page 31)
• 4 - Crimp the contacts
• 5 - Place the contacts in their cavities, checking the retention by slightly pulling the cable
• 6 - Clean the connector surface and the cable jacket with isopropyl alcohol

(Nota: It is advised to rub the jacket with sand paper and clean the jacket before shrinking the boot)

• 7 - Position the boot over the rear threads
• 8 - Heat the boot with a heat gun: minimum shrink temp: 80°C - minimum full recovery temp: 110°C

make sure to apply the heat evenly around the boot. Starting by applying the heat from the rear

of the connector.

Do not apply excessive heat, as it will damage the connector and/or boot.

• 9 - Let the boot cool down
• 10 - Check for good retention and the boot glue grip.