Utl series, Technical information, Ul1977 – Northern Connectors Souriau UTL Series Push-Pull Connectors User Manual

Page 44: Underwriter laboratories, Spacing, Marking

Advertising
background image

44

© 2012 – SOURIAU

UTL Series

Technical information

Underwriter Laboratories

UL1977

Spacing:

For a 250V max connector, distance through air or over material shall be 1.2mm whereas from 250V to 600V connector the spacing is 3.2
minimum. These distances have to be taken between uninsulated live parts as shown in the matrix below:

An alternative way to determine voltage rating is with the Dielectric-Withstand test. If during one minute there is no arc-over or breakdown
the rated voltage is given as given below:

a) 500 volts for a type 1B device
b)

1000 volts plus twice rated voltage for types 1A, 2, 3 and 4 devices.

Applicability of spacing requirements

Type

Uninsulated live part - uninsulated

live part of opposite polarity

Uninsulated live part - uninsulated

grounded metal part

Uninsulated live part - exposed

dead metal part

0

No

No

No

1A

Yes

Yes

Yes

1B

Yes

Yes

No

2

Yes

Yes

Yes

3

Yes

Yes

Yes

4

Yes

Yes

Yes

Marking:

A device shall be legibly marked with the manufacturer's trade name, trade mark, or other descriptive marking by which the organisation
responsible for the product may be identifi ed. (Exception: If the device is too small, or where the legibility would be diffi cult to attain, the
manufacturer’s name, trademark, or other descriptive marking may appear on the smallest unit container or carton)

The following shall be marked on the device or on the smallest unit container or carton or on a stuffer sheet in the smallest unit container or
carton:

a) The catalogue number or an equivalent designation

b) The electrical rating in both volts and amperes, if assigned

c) Whether ac or dc, if restricted
d) Flammability class, if identifi ed

Example - Marking for the arrangement 10-3:

500V 10A UL94 V-0