25

.

34

Han-

Yellock

Features

• Snap-in assembly from mating side and from termi-

nation side

• Wiring with male and female contacts

• Finger safe design

• Fast and tool-less assembly

Current carrying capacity

The current carrying capacity of the connectors is limited by the

thermal load capability of the contact element material including

the connections and the insulating parts. The derating curve

is therefore valid for currents which flow constantly (non-inter-

mittent) through each contact element of the connector evenly,

without exceeding the allowed maximum temperature.

Measuring and testing techniques according to

DIN EN 60 512-5-2

Operating current

Ambient temperature

➀ wire gauge: 1.5 mm²
➁ wire gauge: 2.5 mm²
➂ wire gauge: 4 mm²

Technical characteristics

Specifications

DIN EN 60 664-1

DIN EN 61 984

Monoblocks

Electrical data

acc. to EN 61 984

16 A 500 V 6 kV 3

Rated current

16 A

Rated voltage

500 V

Rated impulse voltage

6 kV

Pollution degree

3

Pollution degree 2 also

16 A 690 V 8 kV 2

Insulation resistance

≥ 10

10

Ω

Material

polycarbonate

Limiting temperatures

-40 °C ... +125 °C

Flammability acc. to UL 94

V 0

Mechanical working life

- mating cycles

≥ 500

Contacts

Material

copper alloy

Surface

- hard-silver plated

3 µm Ag

- hard-gold plated

2 µm Au over 3 µm Ni

Contact resistance

≤ 2 mΩ

Crimp terminal

- Wire gauge

0.14 ... 4 mm²

- AWG

26 ... 12

Stripping length

6.5 mm

Tools

see chapter 99